Easy Series Control Panel
Paragraph
Feature
Number in
ANSI/SIA CP-01
4.2.6.1 and 4.2.6.2 Duress Feature
4.3.1
Cross Zoning
4.3.1
Programmable
Cross Zoning Time
4.3.2
Swinger
Shutdown
4.3.2
Swinger
Shutdown Disable
4.3.3
Fire Alarm
Verification
4.5
Call Waiting
Cancel
Programming at installation site might be subordinate to other UL requirements for the intended application.
1
Combined Entry Delay and Abort Window should not exceed 1 minute.
2
3
If the cross zone timer ends and a second cross zone point is not faulted, the system sends an intrusion alarm
unverified report.
1.5

Underwriters Laboratories (UL)

Household Fire Warning System
Household Burglar Alarm Unit
Bosch Security Systems, Inc.
Requirement
Allowed Option
Required Option
Allowed
Required
(programmable)
Allowed
Required option
Required option
Install at least one UL Listed four-wire latching type smoke detector rated to operate over
the voltage range of 11.2 VDC to 12.3 VDC. The maximum smoke detector load is 50 mA.
Install one UL Listed 85 dB audible device rated to operate over the range of 11.2 VDC to
12.3 VDC as required for this application. Program the bell cut-off time for at least four
minutes. Refer to Programming Item 107 in System Programming Items, page 48.
Install end-of-line resistor P/N: 47819 after last smoke detector.
Do not use a printer interface module.
Where two-wire addressable devices are used, do not place fire and intrusion devices on
the same zone.
The system must be able to operate for at least 24 hr, and generate a full alarm output for
at least 4 min without AC power.
Install at least one UL Listed 85 dB audible device rated to operate over the voltage range
of 11.2 VDC to 12.3 VDC.
System Reference Guide
Agency Approvals and Requirements | en
Range
Shipping
Default
No 1+ derivative of
Disabled
another user code;
no duplicates of
other user codes
Programming
Disabled
needed
Can program
Per
manufacturer
For all non-fire
One fault
zones, shut down
at one or two
faults
For non-police
Enabled
response zones
Depends on
Disabled
control panel and
sensors
Depends on user
Disabled
phone line
9
Recommended
Programming
1
Disabled
Enabled and two
or more zones
programmed
Per walk path in
protected
premises
One fault
Enabled (all
zones)
Enabled unless
sensors can self-
verify
Enabled if user
has call waiting
2014.09 | 01 | F.01U.306.221