Easy Series Control Panel
Notice!
Glassbreak detectors are intended only as a component of a perimeter protection system.
Use glassbreak detectors in conjunction with motion detectors.
8.7.2

Testing

Test the detector at least once yearly. Use the Sentrol 5709C hand-held tester to enter the
sensor into test mode and to test the alarm.
Test the sensor alarm
To test the sensor functionality, enter the detector into test mode. In normal mode, the sensor
does not generate an alarm on sound signals from the tester unless the tester is held next to
the sensor.
Each time the sensor alarms, it also goes into test mode for one minute.
Initiating test mode with the Sentrol 5709C hand-held tester:
1.
2.
3.
Performing the alarm test with Sentrol 5709C hand-held tester:
1.
Notice!
If blinds or drapes are present, test the area by holding the hand-held tester behind the
closed blinds or drapes.
2.
Bosch Security Systems, Inc.
Set the tester for tempered or laminated glass, unless the protected glass is plate glass.
Hold the tester on top of the detector.
Activate the tester. The detector alarms and goes into test mode for one minute. During
test mode, the LED blinks continuously. To extend test time, activate the tester within the
range of the sensor at least once each minute.
Hold the tester near the surface of the glass to be protected and aim the speaker at the
sensor. Be sure the tester is at the point on the glass farthest from the detector.
Press the test button on the tester. The LED on the detector stays on for 4 seconds to
indicate the glass is within detection range of the sensor. If the LED does not stay in a
solid state momentarily, but continues to blink, adjust the positioning of the detector so
that it is closer to the window, and re-test. Check the battery strength of the hand-held
testing device before the test.