On an idle control center, press the [i] button to either turn on or off the announcement of
telephone messages through all idle control centers. When you exit the telephone menu and
end the phone session, the system turns Demo Mode off.
142. Restrict Installer Passcode
If set to 0, the Master User must enable the Installer passcode before a person logged in with
the Installer passcode can perform any tasks through the phone menu or RPS; enabling the
Installer passcode grants it Level 3 access. The Installer passcode remains at Level 3 until an
exit delay.
If set to 0, and the Installer is granted access while the control panel is armed, the
programming items are limited.
To enable the Installer Passcode:
1.
2.
3.
145. Test Report Day of Week
Select the day that the control panel sends the test report.
146. Test Report Day of Month
Enter the day of the month that the control panel sends the test report.
148. Arming Beeps/Graduated Annunciation
Select whether the Intrusion and Intrusion and Fire Output Function types beep when the key
fob is used to arm or disarm the control panel.
150. Wireless Jam Detect Level
Configure the jam detect level of the wireless devices.
163. Silence Trouble Tones
Silence annunciation of trouble tones.
164. System Inactivity Time (Hours)
Enter the number of hours that the system must be turned off before it sends the System
Inactive report.
165. System Inactivity Time (Days)
Enter the number of days that the system must be turned off before it sends the System
Inactive report.
166. System Inactivity Time (Weeks)
Enter the number of weeks that the system must be turned off before it sends the System
Inactive report.
168. Audio Verification Command Set
Select the command set that the control panel uses for internal alarm verification. Press the
[*] key on the phone to enable the microphone on the control centers. This allows the central
station operator to hear noise on the premises. This option only effects the button presses on
the phone while an audio verify session is active between the control panel and the central
station operator.
224. RPS Automatic Call In Time (Hours)
202. PSTN or GSM Connection
Select the type of telephone connection the system will use to send reports to the central
station.
203. Voice Format Repeat Count
2014.09 | 01 | F.01U.306.221
From the control center, the Master User enables enters the passcode. When the
validation for the Master User passcode expires, the Installer passcode is enabled.
Using a token, the Master User presents the token several times until the control center
speaks "Turning your system off". If the Master User token is presented again, the
Installer passcode is disabled.
From the phone interface, the Master User enters the passcode, then presses [3] for
System Maintenance, [3] for System Test menu, and then [6] to enable the Installer's
passcode.