7.3.1
You can set the frequency settings by inputting an analog voltage signal of 0 to 10Vdc between the VIA and CC
terminals.
The following shows examples when the run command is input from the terminal.
Title
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
7
Power
Supply
* Connect a single-phase
input model to R/L1 and
S/L2/N.
Settings depending on voltage (0 to 10 V) input
Function
Command mode selection
Frequency setting mode
selection
Analog/logic input selection
(VIA/VIB)
VIA input point 1 setting
VIA input point 1 frequency
VIA input point 2 setting
VIA input point 2 frequency
Analog input filter
MCCB
R/L1
VF-MB1
S/L2
T/L3
FLA
FLB
FLC
PP
CC
VIA
Adjustment range
0 - 4
0 - 11
0 - 4
0 - 100%
0.0 - 500.0Hz
0 - 100%
0.0 - 500.0Hz
2 - 1000 ms
Run and stop settings
Motor
U/T1
IM
V/T2
W/T3
Setting characteristics for the frequency
Forward
run
Connecting and calibrating the
F
R
Reverse
run
RES
S1
S2
S3
CC
+
0 to 10 V
-
G-14
Default setting
Setting example
1
(panel keypad)
(terminal board)
0
(setting dial 1)
(terminal board VIA)
0
(Voltage signal
(0 – 10V))
0
0.0
100
*1
64
You can switch between forward run (F)
and reverser run (R), and run/stop with
external signals.
setting signal and operation frequency
Set characteristics at two points in the
diagram below.
frequency meter
Select the type of meter connected at
and calibrate.
Refer to section 3.4 for details.
Hz
Point 2
Point 1
0%
100%
(0V)
(10 V)
Voltage input
Frequency setting signal
E6581697
0
1
0 - 2
0
0.0
100
50.0/60.0
64
%