Removal and Replacement

Required Service Tools

Required Service Tools
Service of this server requires one or more of the following tools:
Electrically Conductive Field Service Grounding Kit (P/N 9300-1155)
Processor install tool (attached to the processor board assembly)
1/4 inch flat blade screwdriver
ACX-15 Torx screwdriver
ACX-10 Torx screwdriver

Safety Information

Use care to prevent injury and equipment damage when removing and replacing server components. Voltages
can be present within the server. Many assemblies are sensitive to damage by electrostatic discharge (ESD).
Follow the safety conventions listed below to ensure safe handling of components, to prevent injury, and to
prevent damage to the server:
When removing or installing any server component, follow the instructions provided in this guide.
If installing a hot-swappable or hot-pluggable component when power is applied (fans are running),
reinstall the server cover immediately to prevent overheating.
If installing a hot-pluggable component, complete the required software intervention prior to removing
the component.
If installing an assembly that is neither hot-swappable nor hot-pluggable, disconnect the power cable
from the external server power receptacle.
Ensure that the system is powered off and all power sources are disconnected
WARNING
from the server prior to removing or installing server hardware (unless you are
removing or installing a hot-swappable or hot-pluggable component).
Voltages are present at various locations within the server whenever an ac
power source is connected. This voltage is present even when the main power
switch is turned off.
Failure to observe this warning can result in personal injury or damage to
equipment.
Do not wear loose clothing that can snag or catch on the server or on other items.
Do not wear clothing subject to static charge buildup, such as wool or synthetic materials.
If installing an internal assembly, wear an antistatic wrist strap and use a grounding mat, such as those
included in the Electrically Conductive Field Service Grounding Kit (HP 9300-1155).
Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or
any electrical components on accessory boards.
54