Step 2. Log in to the iLO 2 MP for the server and use the
Accessing the console through the iLO 2 MP enables you to maintain console access to the system
after HP OpenVMS has shut down.
Step 3. At the OpenVMS DCL prompt, issue the @SYS$SYSTEM:SHUTDOWN command and specify the
shutdown options in response to the prompts. For example:
>@SYS$SYSTEM:SHUTDOWN
SHUTDOWN -- Perform an Orderly System Shutdown
How many minutes until final shutdown [0]:
Reason for shutdown [Standalone]:
Do you want to spin down the disk volumes [NO]?
Do you want to invoke the site-specific shutdown procedure [YES]?
Should an automatic system reboot be performed [NO]? yes
When will the system be rebooted [shortly via automatic reboot]:
Shutdown options (enter as a comma-separated list):
REBOOT_CHECK
SAVE_FEEDBACK
DISABLE_AUTOSTART
POWER_OFF
Shutdown options [NONE]:
%SHUTDOWN-I-OPERATOR, this terminal is now an operator's console
%%%%%%%%%%%
Operator status for operator _RSNVMS$OPA0:
CENTRAL, PRINTER, TAPES, DISKS, DEVICES, CARDS, NETWORK, CLUSTER, SECURITY,
...
NOTE

Booting and Shutting Down Microsoft Windows

This section describes how to boot and shut down Microsoft Windows on entry class HP Integrity servers and
how to add Windows entries to the system boot options list.
"Adding Microsoft Windows to the Boot Options List" on page 215
"Booting the Microsoft Windows Operating System" on page 217
"Shutting Down Microsoft Windows" on page 217

Adding Microsoft Windows to the Boot Options List

On HP Integrity servers, the operating system installer automatically adds an entry to the boot
NOTE
options list.
To add a Microsoft Windows entry to the system boot options list, follow these steps:
Step 1. Access the EFI Shell environment.
Appendix B
on node RSNVMS
Check existence of basic system files
Save AUTOGEN feedback information from this boot
Disable autostart queues
Request console to power-off the system
OPCOM
12-JUL-2005 18:47:51.01
HP OpenVMS I64 does not support the POWER_OFF shutdown option.
Booting and Shutting Down the Operating System
Booting and Shutting Down Microsoft Windows
menu to access the system console.