HP Integrity rx6600 User's & Service Manual page 296

Hide thumbs Also See for Integrity rx6600:
Table of Contents

Advertisement

Core I/O Card Utilities
Smart Array P600 Controller
Diagnostic Tools
The following diagnostic tools provide feedback about problems with arrays:
ADU
This utility is a Windows-based diagnostic tool that sends an email to HP Support when it detects any
problems with the controllers and attached storage in a system.
To install ADU, follow these steps:
Step 1. Open the \contents\utilities\smartarray directory on the
the cp00xxxx.exe file.
Step 2. When installation is complete, run ADU by clicking
Array Diagnostic Utility
Array Configuration Utility User Guide at:
http://www.docs.hp.com
POST Messages
Smart Array controllers produce diagnostic error messages at reboot. Many of these POST messages are
self-explanatory and suggest corrective actions. For more information about troubleshooting POST
messages, see the server service guide.
Battery Replacement Notice
This component uses a nickel metal hydride (NiMH) battery pack.
WARNING
There is a risk of explosion, fire, or personal injury if a battery pack is mishandled.
To reduce this risk:
Do not attempt to recharge the batteries if they are disconnected from the
controller.
Do not expose the battery pack to water, or to temperatures higher than 60ºC
(140ºF).
Do not abuse, disassemble, crush, or puncture the battery pack.
Do not short the external contacts.
Replace the battery pack only with the designated HP spare.
Battery disposal must comply with local regulations.
You must not dispose of batteries, battery packs, and accumulators together with the general household
waste. To forward them to recycling or proper disposal, use the public collection system or return them by
established parts return methods to HP, an authorized HP Partner, or one of their agents.
For information about battery replacement, contact an authorized reseller or an authorized service provider.
For information about battery disposal, see the HP Safety and Regulatory Guide.
296
. The meanings of the various ADU error messages are provided in the HP
Smart Setup
and selecting
Start
Programs>HP System Tools>HP
media and double-click
Appendix D

Advertisement

Table of Contents
loading

Table of Contents