Figure D-9 Ebsu Maintain Firmware Update Screen - HP Integrity rx6600 User's & Service Manual

Hide thumbs Also See for Integrity rx6600:
Table of Contents

Advertisement

Core I/O Card Utilities
Smart Array P600 Controller
EBSU displays the firmware update screen for the selected device.
The version number in the first column (ROM Firmware Version) is the one currently installed
on your system.
The version number in the second column (ROM Version on Disk) is the one available on your
Smart Setup media.

Figure D-9 EBSU Maintain Firmware Update Screen

Step 9. Compare the two version numbers and perform one of the following options:
If the number in the first column is the same or higher than the number in the second column,
your installed firmware is current. You do not need to update the firmware for this device! You
can exit EBSU and quit this procedure.
If the number in the first column is less than the number in the second column, your installed
firmware is older than the version on your Smart Setup media. You must update the firmware
for this device! Proceed to Step 9 and continue from there.
NOTE
Step 10. Use the tab key to scroll down into the
Step 11. Press
to select the device (this puts an "X" inside the box on the left side of the device name).
Enter
Step 12. Use the tab key to move to the
The firmware update begins and proceeds automatically to completion.
278
The utility does not allow you to flash the firmware if the installed version is the
same or higher than the version on the Smart Setup media.
selection and press
OK
section and highlight the device name.
Device
.
Enter
Appendix D