Required Service Tools - HP 9000 rp3410 User's & Service Manual

Hide thumbs Also See for 9000 rp3410:
Table of Contents

Advertisement

Removing and Replacing Components

Required Service Tools

If installing an assembly that is not hot-swappable, disconnect the power cables from the server external
power connectors.
Ensure that the server is powered off and all power sources have been
WARNING
disconnected from the server before working with the server.
Voltages are present at various locations within the server whenever an ac
power source is connected. This voltage is present even when the main power
switch is in the off position.
Failure to observe this warning can result in personal injury or damage to
equipment.
Do not wear loose clothing that can snag or catch on the server or on other items.
Do not wear clothing subject to static charge build-up, such as wool or synthetic materials.
If installing an internal assembly, wear an antistatic wrist strap and use a grounding mat, such as those
included in the Electrically Conductive Field Service Grounding Kit (HP 9300-1155).
Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or
any electrical components on accessory boards.

Required Service Tools

Service of this product may require one or more of the following tools:
Electrically Conductive Field Service Kit (HP part number 9300-1155)
1/4 inch flat blade screwdriver
ACX-15 Torx® screwdriver
Special processor tool kit (HP part number 5069-5441)
148
Chapter 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9000 rp3440

Table of Contents