Removing and Replacing Components

Safety Information

Follow the procedures listed below to ensure safe handling of components and to prevent harm to both you
and the HP Server:
Use an antistatic wrist strap and a grounding mat, such as those included in the Electrically Conductive
Field Service Grounding Kit (HP 9300-1155)
Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or
any electrical components on accessory boards
Do not wear clothing subject to static charge build-up, such as wool or synthetic materials
WARNING
Hazardous voltages are present inside the HP Server. Always remove AC power
from the server and associated assemblies while working inside the unit. Serious
injury may result if this warning is not observed.

Service Tools Required

Service of this product may require one or more of the following tools:
Electrically Conductive Field Service Kit (P/N 9300-1155)
1/4 inch flat blade screwdriver
ACX-15 Torx screwdriver

Accessing a Rack Mounted Server

The hp 9000 rp4440 Server is designed to be rack mounted. The following procedure explains how to gain
access to your HP Server that is mounted in an approved rack. For rack installation instructions, review the
document titled Installation Guide, Mid-Weight Slide Kit, 5065-7291. This document can be accessed at
http://www.hp.com/racksolutions.
WARNING
Ensure that all anti-tip features (front and rear anti-tip feet installed; adequate
ballast properly placed; and so on) are employed prior to extending the server.