Service Tools Required

Service of this product can require the following tools:
An IPF Processor Install Tool Kit, consisting of:
Disposable ESD Kit
Processor installation tool (2.5 mm hex and Torx 15 screwdriver)
NOTE:
included with the processor.
The server blade has a Torx T–15 screwdriver mounted on the inside of the access panel.

Adding a Hot-Plug SAS Disk Drive

Use the following procedures if the server blade has a disk drive blank installed and you need to
install a hot-plug SAS disk drive.
For a list of supported SAS disk drives for the server blade, see:
products/blades/components/c-class-storage.html
1.
Press the release buttons simultaneously. See
2.
Pull the blank out of the drive bay.
Figure 9 Removing a Disk Drive Blank
CAUTION:
blank. Operating the server blade without a SAS disk drive or disk drive blank causes improper
airflow and cooling that can lead to thermal damage to the server blade.
To install a SAS disk drive:
1.
Slide the drive into the cage until it is fully seated (1).