Extending the Server from the Rack
Ensure that there is enough area (approximately 1.5 meters [4.5 ft.]) to fully extend the server
NOTE
from the front of the rack.
To extend the server from the rack, follow these steps:
Step 1. Remove the T25 screws with the orange tags that fasten the front of the server to the rack
(Figure 4-1).
Step 2. Remove the orange screws from the rear of the rack located on the left and right slide rails.
Step 3. Flip out the two pull handles located on both ends of the front bezel (Figure 4-1).
Step 4. Slowly pull the server forward by the handles until it is fully extended.
NOTE
Figure 4-1
Rack Screw Location
Inserting the Server into the Rack
To insert the server into the rack, follow these steps:
Step 1. Press the rail clips on both sides of the server inward.
Step 2. Push the server into the rack until it stops.
Chapter 4
The server is fully extended when the rail clips are locked in place and the top cover
is completely accessible.
Pull Handles
Screw Location is Behind Handles
Removal and Replacement
Accessing a Rack-Installed Server
UID
INIT
57