FIXING UNIT
[4]

SD4 (Cleaning Web SD) Control

24VDC
24VDC
PGND
PGND
DCPS
SD4 (cleaning web SD) is controlled by the PRDB (printer
drive board).
1.
Operation
SD4 (cleaning web SD) is set ON by PS2 (fixing exit
PS), stays ON for 100msec, and then goes OFF.
However, that SD4 does not come at all for certain
copy counts.
2.
Signals
a.
Output signal
(1) SD4 DRIVE (PRDB −> SD4)
[L]: SD4 ON
[H]: SD4 OFF
24VDC
24VDC
PGND
PGND
M1
LOCK SIG
M1 CLK
M1 CONT
5VDC
SGND
24VDC
SD4
SD4 DRIVE
PRDB
2-K-4