2.
Setting the KRDS connection recognition
(1) Plug the power cord of the copier to the outlet.
(When the SW1 (main power) and SW2 (sub
power) of the copier remain off.)
(2) Turn on the SW1 (main power) when the SW2 (sub
power) remains off.
(3) Turn on the SW2 (sub power) while pressing [2]
and [5] of the copy quantity setting buttons
simultaneously.
(4) Select the [1. Software SW] key on the 25 mode
menu screen.
(5) Select the bit No.6 of the switch No.12, and then
press the [ON] key.
ON:
KRDS recognize
OFF: KRDS not recognized
Note:
3.
Initializing KRDS memory
(1) Turn off the SW2 (sub power) when the SW1 (main
power) remains on.
(2) Turn on the SW2 (sub power) while holding down
[4] and [7] of the copy quantity setting buttons
simultaneously.
(3) Press the start print button after pressing the copy
3
quantity setting button [1], [5] and [
[9], [8], finally [
I/O check mode
< 15 - 98 > IN: – – OUT: NOW
(4) "NOW" indication will be changed to "FIN" on the
message display.
(5) Turn off the SW2 (sub power).
If the copier software DIPSW 12-6 (KRDS
recognition) is not selected to "1", the
menu of the KRDS can not be selected.
] button, then
*
] button again.
*
4.
Setting KRDS software SW
This function allows adjustment of the KRDS software
switches.
Note:
Adjust the software switch while checking
the switch and bit number since the
memory is rewritten every time the bit data
(1 or 0) is changed.
Any bit data that has been incorrectly
changed must be returned to the original
data.
Step
Operation procedure
1
Enter the 25 mode.
2
[25 mode menu screen]
Press the [9. KRDS setting ] key.
3
[KRDS setting menu screen]
Press the [4. KRDS software SW set] key.
4
[KRDS software SW set screen]
Use the [ ] or [ ] keys to set the switch number.
(Refer to *1)
5
Use the [ ] or [ ] keys to set the bit number.
(Refer to *1)
6
Press the [ON] of [OFF] key to set the bit data.
7
Press the [RETURN] key to end the setting.
*1:
The bit of the switch is written in the non-volatile
memory every time it is changed.
The numbers shown in the message area are
defined as follows:
For each switch function, refer to "List of KRDS
Software DIP SW".
6-3
KRDS