External Section; Replacing The Ozone Filter - Konica Minolta 7020 Service Manual

Hide thumbs Also See for 7020:
Table of Contents

Advertisement

HOME

EXTERNAL SECTION

[1]

Replacing the Ozone Filter

Caution: Be sure that the power cord has
a. Procedure
(1) Remove the five set screws, and remove the read
right cover.
Note: If an unusual noise is emitted when you open
or close the bypass tray, clean the ADU door
rib with alcohol.
(2) Remove the ozone filter.
2
been unplugged from the outlet.
Set screws
Read right
cover
Rib
PET sheet
<7020/25/30
only>
Ozone filter
(3) Reinstall the above parts following the removal
steps in reverse.
How to install the ozone filter
PET sheet
Caution: When installing the ozone filter, take care
not to break it.
3-A-1
EXTERNAL SECTION
Push the PET sheet
firmly against the
rear.
Ozone filter
Insert the front part.
Shift the front part to
eliminate clearance.

Hide quick links: