Konica Minolta 7020 Service Manual page 336

Hide thumbs Also See for 7020:
Table of Contents

Advertisement

HOME
LIST OF WARNING (ERROR) CODES
Warning
Classification
CB (overall
E89-6
control board)
communication
abnormalities
Note: For details of E86-xx and other FAX-related error codes, refer to the FK service handbook.
About abnormal units isolation
The following table shows how defective units are cut off (by software) in accordance with the error type.
Error code
18-1
18-2
18-3
18-4
60-1, -9, 67-1, -3
70-1, -9, -11
77-2
77-3, -16
77-5
3
77-6, -11
77-18
3
86-2, -3
87-2, -3
Unit isolation Method
Upon the occurrence of any of the error codes shown above, the defective unit will be cut off from the system (by
software) when you press the [AUTO RESET] key and then switching SW2 (sub power) OFF/ON. Other functions will
remain available. Note that if you don't clear the problem in the defective unit, the error will be detected again (and the
error code displayed again) the next time you turn SW2 OFF/ON. (This cutoff feature is effective one time only.)
Note: If F70-1, -9, -11 or 77-2, -5, -18 occurs, you cannot separate the unit concerned using the above procedure. In this
3
case, you must either remove the cause of the error code or remove the FNS, otherwise printing will not take place.
Causes
code
Sub power switch OFF processing
wait timeout
Error
Error in main body upper tray
Error in main body lower tray
Error in DB upper tray
Error in DB lower tray (LCT)
RADF error
FNS error (Note)
Error in FNS tray up/down drive (Note)
Error in FNS alignment-plate,
pressure motor
Error in FNS paper-pressure motor
FNS stapler error
Error in FNS cooling fan motor
Fax-board error
Printer-board error
Resulting
Correction
operation
Main relay and 24 V
Switch SW2 (sub
power supply go
power switch)
OFF at the end of
OFF/ON. (CB
copying.
reset)
All indicators on the
operation panel
light.
Unit to be cut off
Main body upper tray
Tray can not be selected.
Main body lower tray
Tray can not be selected.
DB upper tray
Tray can not be selected.
DB lower tray, LCT
Tray can not be selected.
RADF
RADF can not be used.
FNS
FNS can not be used; FNS must be removed.
FNS
FNS can not be used; FNS must be removed.
FNS alignment unit
Only straight exit remains available.
FNS
FNS can not be used; FNS must be removed.
FNS alignment unit
Only straight exit remains available.
FNS
FNS can not be used; FNS must be removed.
Copying and printing remain enabled.
Fax
Printer
Copying and faxing remain enabled.
8-42
Estimated abnormal parts
CB (overall control board)
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

703070227130713570257035