Other Controls; Parts Energized When The Main Power Switch Is Off; Components Operated By Power Switches Sw1 And Sw2 - Konica Minolta 7020 Service Manual

Hide thumbs Also See for 7020:
Table of Contents

Advertisement

HOME

OTHER CONTROLS

[1]
Parts Energized When the Main
Power Switch is OFF
The following components are powered regardless of
whether the SW1 (main power switch) is ON or OFF,
provided that the power cord remains plugged in.
a.
CBR1 and CBR2 (circuit breakers)
The circuit breakers serve to protect against damage
from short circuit. If current exceeds 8A, the circuit
breaker(s) will go OFF, cutting the power to the
system.
b. DCPS (DC power supply)
Supplies power to each unit and also controls the
ON/OFF state of the fixing lamp.
SW1
CBR1
CBR2
DCPS
[2]
Components Operated by Power
Switches SW1 and SW2
2
12VDC
-12VDC
5VDC
SGND
12VDC
-12VDC
5VDC
SGND
24VDC
SW1
PGND
5VDC
SGND
24VDC
AC(H)
PGND
AC(N)
5VDC
SGND
PTC
24VDC
12VDC
PGND
-12VDC
5VDC
SGND
24VDC
PGND
5VDC
SGND
24VDC
PGND
12VDC
5VDC
SGND
DCPS
2-M-1
OTHER CONTROLS
OB
PRNCB
12VDC
-12VDC
5VDC
SGND
FAXCB
NCUCB
FS-107
SW2
SUB SW
SGND
PSWB
DB-209/210
DB-409/410
5VDC
LCD
SGND
OB
12VDC
5VDC
CCD
-5VDC
SGND
ADB
24VDC CONT
5VDC CONT
5VDC
LDB
SGND
5VDC
INDEX
SGND
CB
24VDC
PGND
DF-314
5VDC
SGND
SCDB
24VDC
HV
PGND
24VDC CONT
RL CONT
PRDB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

703070227130713570257035