Loading Door Assembly; Door Hinge; Loading Door Handle - ALLIANCE AT050L Service Manual

Drying tumblers
Hide thumbs Also See for AT050L:
Table of Contents

Advertisement

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.

47. LOADING DOOR ASSEMBLY

Refer to Figure 7.
a. Open loading door.
b. Remove screw from lower hinge cam.
c. While supporting lower hinge cam, raise door
to clear setscrew located in cam.
d. Slide lower cam down and out of hinge lug.
e. Lift door assembly up and out of hinge lug.
HINGE CAM
Figure 7
70269301
UPPER
SCREW
LOWER
DOOR
HINGE CAM
HINGE
LUG
T252SE1C
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING

48. DOOR HINGE

Refer to Figures 7 and 8.
a. Remove door assembly.
b. Remove nuts and screws holding hinge to door
frame.
DOOR
HANDLE
SCREW

49. LOADING DOOR HANDLE

Refer to Figure 8.
a. Open loading door.
b. Remove screws holding door handle to door
frame.
Section 5 Service Procedures
HINGE
DOOR
FRAME
NUT
DOOR
HANDLE
Figure 8
W002
DOOR
FRAME
SCREW
T301SE1B