NEC NEAX 2000 IPS Installation Manual page 435

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

SWITCH NAME
JP1 (Jumper pin)
JP2 (Jumper pin)
JP3 (Jumper pin)
JPRI (Jumper pin)
JPR (Jumper pin)
JPT (Jumper pin)
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When using the AP Number 64 to 93 (for AP Number extension) in accommodating the PRT
card on Remote site, be sure to set the SENSE switch and SW1-4 switch of all the PRT cards to
be accommodated to AP Number 31. Also, set AP Number to any one between 64 and 93 by
CM05 for each PRT card. If a different site is used to accommodate the PRT card, be sure to
set switches similarly.
[Series 3800 software or later required]
NOTE 3:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH
SETTING
NUMBER
POSITION
RIGHT
LEFT
RIGHT
LEFT
RIGHT
LEFT
LEFT
RIGHT
LEFT
RIGHT
LEFT
FUNCTION
Set the line impedance.
JP1
JP2
LEFT
RIGHT
LEFT
LEFT
RIGHT RIGHT
RIGHT
LEFT
Balanced transmission
(For twisted-paire cable) (for T1/E1)
Unbalanced transmission
(For coaxial cable) (for E1)
Not used
Neutral grounding on the receiving line
is provided.
Neutral grounding on the receiving line
is not provided.
Neutral grounding on the transmitting
line is provided.
Neutral grounding on the transmitting
line is not provided.
– 419 –
PN-DTB (CCT/DTI/PRT)
LINE IMPEDANCE
100Ω (for T1)
110Ω (for T1)
120Ω (for E1)
75Ω (for E1)
Continued on next page
NWA-008841-001 Rev.5.0
CHECK
90ch3003.fm
JULY/15/2007

Hide quick links:

Advertisement

Table of Contents
loading