NEC NEAX 2000 IPS Installation Manual page 366

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

NOTE 3:
The system can receive clock signals from two clock supply routes.
In normal condition, the system synchronizes to the clock signals supplied on the PLO0 of MP
card via the Back Wiring Board, and if the clock signals are failed, the clock supply route takes
over to PLO1 automatically. Set SW11-2 and SW11-3 as follows.
BRT0
CONDITIONS
SW
11-2
When one BRT
ON ON
is provided.
When more
than one BRT is
ON ON ON OFF OFF ON ---- OFF ON
provided.
NOTE 4:
Mount the BRT card which receives a source clock signals into PIM0.
BRT1
BRT2
SW
SW
SW
SW
11-3
11-2
11-3
11-2
----
BRT23
SW
SW
SW
----
11-3
11-2
11-3
– 350 –
PN-2BRTK (BRT)
REMARKS
MP card will receive the
clock signal from No.0 circuit
of BRT0 at its PLO0 input.
Should a clock failure occur
with No.0 circuit, MP card
will switch to No. 1 circuit of
BRT0.
MP card will receive the
clock signal from BRT0 at its
PLO0 input, under normal
conditions.
Should a clock failure occur
with both No.0 and No.1 cir-
cuits of BRT0, MP card will
switch to the PLO1 input
which gets clock from BRT1.
NWA-008841-001 Rev.5.0
90ch3003.fm