• Hanging PIM to HANGER ASSEM
(1) Secure the HANGER ASSEM to the surface of a wall with three screws.
Select screws to match with the wall type as follows.
WALL TYPE
CONCRETE
WOOD
PLASTER BOARD
[THICKNESS Minimum 9.6 mm (0.38 inch)]
A concrete wall is recommended because it is the most firm to mount the PBX of the three. The
plaster board is the most infirm wall of the three.
(2) Hang the slits of the rear of a PIM to the hooks of the HANGER ASSEM.
(3) Secure the PIM to the HANGER ASSEM with two screws.
NOTE:
Screws are attached to the HANGER ASSEM.
SCREWS
ANCHOR BOLT TYPE
WOOD TYPE SCREWS
MOLLY ANCHOR TYPE
Hanging PIM to HANGER ASSEM
HOOK
FRONT
– 102 –
CHAPTER 2 INSTALLATION
INSTALLATION OF MAIN EQUIPMENT
RECOMMENDED SCREW
Recommended 4 mm (0.16 inch)
by 25 mm (0.98 inch)
Minimum 3.5 mm (0.14 inch) DIA
Maximum 4.5 mm (0.17 inch) DIA
Minimum 3.5 mm (0.14 inch) DIA
Maximum 4.5 mm (0.17 inch) DIA
HANGER ASSEM
HOOK
PIM
BASE
NWA-008841-001 Rev.5.0