NEC NEAX 2000 IPS Installation Manual page 360

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

SWITCH NAME
SW11 (Dip SW)
ON
1 2 3 4
The figure in the SWITCH NAME column and the position of
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH
SETTING
NUMBER
POSITION
ON
1
OFF
ON
2
NOTE 3
OFF
ON
3
NOTE 3
OFF
ON
4
OFF
FUNCTION
For normal operation
Not used
Source clock signal from network is
sent to the PLO of MP card according
to the switch setting of SW11-3.
Source clock signal from network is not
sent to the PLO of MP card.
Output clock signals to the PLO0 of MP
card.
Output clock signals to the PLO1 of MP
card.
AP No. 04-15
AP No. 20-31
– 344 –
PN-2BRTC (BRT)
in the SETTING POSITION col-
Continued on next page
NWA-008841-001 Rev.5.0
CHECK
90ch3003.fm