Initial Installation Procedures for the CP3002-RC

The following procedures are applicable only for the initial installation of the CP3002-RC in a
system. Procedures for standard removal of the CP3002-RC are found in their respective chap-
ters.
Warning!
To operate the CP3002-RC, 3U CompactPCI backplane with maximum five
slots and rear I/O support on the system slot is required. Do not plug a rear I/O
configured board in a backplane without rear I/O support. Failure to comply
with the above will result in damage to your board.
To perform an initial installation of the CP3002-RC in a system, proceed as follows:
1. Ensure that the safety requirements indicated Chapter 3.1 are observed.
Warning!
Failure to comply with the instruction below may cause damage to the
board or result in improper system operation.
2. Ensure that the board is properly configured for operation in accordance with application
requirements before installing. For information regarding the configuration of the
CP3002-RC refer to Chapter 4. For the installation of CP3002-RC specific peripheral de-
vices and rear I/O devices refer to the appropriate sections in Chapter 3.
Warning!
Care must be taken when applying the procedures below to ensure that
neither the CP3002-RC nor other system boards are physically damaged
by the application of these procedures.
3. To install the CP3002-RC perform the following:
1. Ensure that no power is applied to the system before proceeding.
2. Ensure that the extractor handle retaining screw is properly fastened.
3. Before inserting the board in the system chassis, ensure that both the top and bottom
wedge-locks are fully relaxed.
To relax the wedge-lock, turn the wedge-lock's screw counter-clockwise using a
2.5 mm hex key until the screw is against the stop. The screw should turn lightly. If,
when turning the screw, perceptible resistance is encountered, it is at the stop. Do not
apply more force than necessary.
4. Carefully insert the board into the slot designated by the application requirements for
the board until it makes contact with the backplane connectors.
Note ...
In ruggedized systems, the slot tolerances are very narrow. In the event
the board jams during insertion, remove it and ensure that both wedge-
locks are fully relaxed before proceeding with insertion. The board should
allow insertion to the point of contact with the backplane connectors with-
out applying undo force.