Cp308 Initial Installation Procedures - Kontron CP308 User Manual

3u compactpci processor board based on the intel core 2 duo processor with the mobile intel gs45 express chipset
Table of Contents

Advertisement

Installation
3.2

CP308 Initial Installation Procedures

The following procedures are applicable only for the initial installation of the CP308 in a system.
Procedures for standard removal and insertion/removal under power are found in their respec-
tive chapters.
To perform an initial installation of the CP308 in a system proceed as follows:
1. Ensure that the safety requirements indicated in Chapter 3.1 are observed.
Warning!
Failure to comply with the instruction below may cause damage to the
board or result in improper system operation.
2. Ensure that the board is properly configured for operation in accordance with application
requirements before installing. For information regarding the configuration of the CP308
refer to Chapter 4. For the installation of CP308-specific peripheral devices and rear I/O
devices refer to the appropriate sections in Chapter 3.
Warning!
Care must be taken when applying the procedures below to ensure that
neither the CP308 nor other system boards are physically damaged by
the application of these procedures.
3. To install the CP308 perform the following:
1. Ensure that no power is applied to the system before proceeding.
Warning!
Even though power may be removed from the system, the CP308 front
panel cables and, when installed, the RIO transition module front panel ca-
bles may have power applied which comes from an external source.
In addition, these cables may be connected to devices that can be dam-
aged by electrostatic discharging or short-circuiting of pins.
It is the responsibility of the system designer or integrator to ensure that
appropriate measures are taken to preclude damage to the system or inju-
ry to personnel which may arise from the handling of these cables (con-
necting or disconnecting).
Kontron disclaims all liability for damages or injuries resulting from failure
to comply with the above.
Warning!
When performing the next step, DO NOT push the board into the back-
plane connectors. Use the ejector handle to seat the board into the back-
plane connectors.
2. Carefully insert the board into the slot designated by the application requirements for
the board until it makes contact with the backplane connectors.
Page 3 - 4
CP308
ID 1027-4487, Rev. 3.0

Hide quick links: