CP3002-RC/CP3002-RA
5.
Power Considerations
5.1
System Power
The considerations presented in the ensuing chapters must be taken into account by system
integrators when specifying the CP3002-RC/CP3002-RA system environment.
5.1.1
CP3002-RC/CP3002-RA Baseboard
The CP3002-RC/CP3002-RA baseboard itself has been designed for optimal power input and
distribution. Still it is necessary to observe certain criteria essential for application stability and
reliability.
The table below indicates the absolute maximum input voltage ratings that must not be exceed-
ed. Power supplies to be used with the CP3002-RC/CP3002-RA should be carefully tested to
ensure compliance with these ratings.
Table 5-1:
Maximum Input Power Voltage Limits
SUPPLY VOLTAGE
3.3 V
5 V
Warning!
The maximum permitted voltage indicated in the table above must not be
exceeded. Failure to comply with the above may result in damage to your
board.
The following table specifies the ranges for the different input power voltages within which the
board is functional. The CP3002-RC/CP3002-RA is not guaranteed to function if the board is
not operated within the prescribed limits.
Table 5-2:
DC Operational Input Voltage Ranges
INPUT SUPPLY
VOLTAGE
3.3 V
5 V
ID 1039-3625, Rev. 1.0
MAXIMUM PERMITTED
VOLTAGE
3.6 V
5.5 V
ABSOLUTE RANGE
3.2 V min. to 3.47 V max.
4.85 V min. to 5.25 V max.
Power Considerations
RECOMMENDED RANGE
3.3 V min. to 3.47 V max.
5.0 V min. to 5.25 V max.
Page 5 - 3