Printer System: Smears On Back Of Paper - Konica Minolta bizhub 362 Service Manual

Field service
Hide thumbs Also See for bizhub 362:
Table of Contents

Advertisement

Field Service Ver. 1.0 Dec. 2008
20.3.15

Printer System: Smears on back of paper

A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Paper Path
2
Transfer Roller
3
Fusing Unit
4036fs4062c0
Check Item
Toner is on the paper path.
Transfer Roller is dirty.
Fusing Roller is dirty.
20. Image quality problem
AA
AA
4036fs4063c0
Result
YES
Clean.
YES
Change Transfer Roller
Unit.
YES
Change Fusing Unit.
Action