18. Malfunction code
18.3.20

C4001: Main Body Communication Failure

MFBS Board (MFBS)
Step
Check the MFBS connector for proper connection,
1
and correct as necessary.
Check the PWB-A connector for proper connection,
2
and correct as necessary.
Check the flat cable between MFBS and PWB-A for
3
proper connection, and correct as necessary.
Turn OFF the Main Power Switch, wait for 10 sec. or
4
more, and turn ON the Main Power Switch.
5
Change MFBS
6
Change PWB-A
18.3.21

C4002: HSYNC Detection Failure

PH Unit (PH)
Step
Turn OFF the Main Power Switch, wait for 10 sec. or
1
more, and turn ON the Main Power Switch.
Check the PH and the PWB-A connectors for proper
2
connection, and correct as necessary.
3
Change PH
4
Change PWB-A