Field Service Ver. 1.0 Dec. 2008
MODE
Bit:
006
Bit
Feature
7
Select dial line speed (DP
speed). (PSTN1) *
6
5
Select a line type (tone or
pulse) for calling (Switch
PB/DP). (PSTN1) *
4
Select standard phone
line connected with the
system (Extension / Exter-
nal line connection).
(PSTN1) *
1
Select PSTN port auto-
matically:
Specify how to dial stan-
dard phone lines. <**>
NOTE
• The features with (*) are settable by users. *: Screen setting <*>: Soft switch setting
The feature with [**] (Bit 1) is available only in a system with a multi-port option.
• For PSTN2, see mode 011.
Factory setting bit
7 6 5 4
3 2 1 0
0 1 0 1
0 0 1 0
Logic
0
1
Bit 7-6:
00
01
10
11
DP
PB
Exten-
External
sion con-
line con-
nection
nection
No
Yes
11. Soft Switch Settings
HEX:32
Description
10 pps
This is valid only when
"Switch PB/DP (MODE
20 pps
006 Bit5)" sets DP.
16 pps
16 pps is unavailable to
Not available
users.
DP : pulse
PB : tone
• When the system has 2 PSTN lines
and one of them is used, you can use
the other line by selecting "Yes."
If you have only 1 PSTN line or wish to
use 2 lines for the extension and the
external lines separately, select "No."