6. Other
6.4.12
Scanner Rails
[1]
6.4.13
Bushings
1. Remove the IR Upper Left Cover.
See P.50
2. Remove the Front Holding Bracket.
See P.50
3. Remove the Original Glass.
See P.50
4. Remove the Exposure Unit.
See P.79
[1]
6.4.14
Mirrors
1. Remove the IR Upper Left Cover.
See P.50
2. Remove the Front Holding Bracket.
See P.50
3. Remove the Original Glass.
See P.50
[1]
102
1. Remove the IR Upper Left Cover.
See P.50
2. Remove the Front Holding Bracket.
See P.50
3. Remove the Original Glass.
See P.50
4. Using a soft cloth dampened with
alcohol, wipe four Scanner Rails [1]
4040F2C704DA
clean of dirt.
5. Using a soft cloth dampened with
[1]
alcohol, wipe three Bushings [1]
clean of dirt.
NOTE
• When installing the Exposure Unit,
be sure to perform scanner position
adjustment.
4040F2C702DA
See P.228
4. Using a soft cloth dampened with
alcohol, wipe two Mirrors [1] clean of
dirt.
[1]
4040F2C576DA
Field Service Ver. 1.0 Dec. 2008