Konica Minolta bizhub 362 Service Manual page 502

Field service
Hide thumbs Also See for bizhub 362:
Table of Contents

Advertisement

Field Service Ver. 1.0 Dec. 2008
MODE
Bit:
362
Bit
5
Calling interval during net-
work communication
4
3
2
1
MODE
Bit:
363
Bit
Feature
6
SMTP expansion prohib-
ited (Network function)
5
Specify From address for
DSN report transmission
(Network function)
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
1 0 1 0
Feature
0
Bit 5-1:
Factory setting bit
7 6 5 4
3 2 1 0
0 0 1 0
0 0 0 0
Logic
0
Permit-
ted
Address
specified
11. Soft Switch Settings
HEX: 8A
Logic
1
00000
Not available • This setting is avail-
00001
1sec
00010
2sec
00011
3sec
00100
4sec
00101
5sec
00110
6sec
00111
7sec
01000
8sec
01001
9sec
01010
10sec
Others
Not available
HEX:20
1
Prohib-
Select either "Permitted" or "Prohibited"
ited
for SMTP expansion protocol.
• Valid after the power is turned off and
on.
Address
Chain mail can be prevented by specify-
not spec-
ing an address for DSN report on some
ified
systems.
Description
able for network
communication and
reduces only the
interval from when
the communication
complete to when
the next communica-
tion starts. For re-dial
interval or document
re-sending interval,
apply FAX specifica-
tion.
• Communication
modes that apply the
calling interval during
network communica-
tion
• PC (mail), PC (scan-
ner), PC (FTP), PC
(SMB), PC (HDD), IP
address FAX, Inter-
net FAX, IP relay
(sending order)
Description
115