6. Mechanical adjustment
6.2
Registration (FD)
NOTE
Make this adjustment after any of the following procedures has been performed.
• When the PH Unit has been replaced.
• When the image on the copy is offset in the FD direction.
1. Display Tech. Rep. Mode.
See P.154 of the main body service manual.
22
2. Press the Stop key followed by the
Start key to display the Adjust Mode.
3. Touch the [Printer].
4061F3E523DA
4. Touch the [Registration (FD)].
4061F3E524DA
5. Touch the [Test Print].
4061F3E527DA
6. Touch the [Tray 3].
7. Press the Start key.
4061F3E526DA