Field Service Ver. 1.0 Dec. 2008
MODE
Bit:
370
Bit
Feature
7
Number of times for addi-
tional retransmission
6
(Network function)
5
4
3
2
1
0
MODE
Bit:
371
Bit
Feature
7
Intervals between addi-
tional retransmissions
6
(Network function)
5
4
SMTP server switching
1
Binary Division *
0
Page Division *
NOTE
• The features with (*) are settable by users. *: Screen setting
Factory setting bit
7 6 5 4
3 2 1 0
1 1 1 1
1 1 1 1
Logic
0
1
Bit 7-0:
00000000 0
00000001 1
11111111 255
Factory setting bit
7 6 5 4
3 2 1 0
0 1 0 0
0 0 0 0
Logic
0
1
Bit 7-5:
000
001
010
011
100
Others
OFF
ON
OFF
ON
OFF
ON
11. Soft Switch Settings
HEX:FF
Description
Specify additional retrial
times after retrying the
number of times speci-
|
fied by the user.
"0" indicates no addi-
tional retrial.
Retrial operations will
end after retrying E-mail
transmissions the cur-
rent number of times
specified by the user.
HEX:40
Description
10 min
15 min
20 min
25 min
30 min
Not available
Register two SMTP servers and specify
whether or not to switch at the time of
TX error.
119