Field Service Ver. 1.0 Dec. 2008
Code
C2654
EEPROM Failure
Abnormal Image Transfer
C2702
Voltage
C3451
Fusing Warm-Up Failure (Main)
C3452
Fusing Warm-Up Failure (Sub)
High Fuser Temperature Failure
C3751
(Main)
High Fuser Temperature Failure
C3752
(Sub)
Low Fuser Temperature Failure
C3851
(Main)
Low Fuser Temperature Failure
C3852
(Sub)
Main body Communication
C4001
Failure
C4002
HSYNC Detection Failure
C4101
Polygon Motor Failure
Item
• An EEPROM where no initial data is written is
detected.
• The image transfer voltage exceeds 100 V for
the set period of time while the IU Motor remains
stopped.
• The Fusing Roller Thermistor does not detect
the required temperature within 30 sec. after a
warmup cycle has begun; therefore, the copier
does not complete the warm-up cycle.
• The temperature of the Fusing Rollers does not
reach the required level even after the set period
of time has elapsed during a warm-up cycle.
• The Fusing Roller Sub Thermistor does not
detect the required temperature within 30 sec.
after a warm-up cycle has begun; therefore, the
copier does not complete the warm-up cycle.
• The temperature of the Fusing Rollers does not
reach the required level even after the set period
of time has elapsed during a warm-up cycle.
• The Fusing Roller Thermistor and Fusing Roller
Sub Thermistor are detected to be at a tempera-
ture above 240 °C when the Main Power Switch
is set to ON.
• The Fusing Roller Thermistor and Fusing Roller
Sub Thermistor are detected to be at a tempera-
ture below 105 °C during standby.
• The Fusing Roller Thermistor and Fusing Roller
Sub Thermistor are detected to be at a tempera-
ture below 105 °C during printing.
• Communications with the Mechanical Control
Board and the MFBS Board fail.
• No SOS falling edges are detected within the set
period of time after laser emission began while
the Polygon Motor is turning.
• No SOS falling edges are detected while VIA
remains ON.
• The Polygon Motor Lock signal could not be
detected within the set period of time after the
Polygon Motor is energized. (Faulty start detec-
tion)
• No First Lock signals are detected during the 1-
second period that starts 1 second after a First
Lock signal. (Faulty lock signal detection)
• The Polygon Motor Lock signal could not be
detected after the set period of time has elapsed
while the Polygon Motor is turning. (Out-of-timing
lock detection)
• The Polygon Motor Lock signal is set to ON for
longer than the set period of time while the Poly-
gon Motor remains stopped. (Abnormal lock
detection)
18. Malfunction code
Description
Rank
B
B
A
A
A
A
A
A
B
B
B