Water Fault Finding - Swift Tourer Owner's Handbook Manual

Owner’s service and warranty handbook
Table of Contents

Advertisement

WATER
Fault
Cause
Water not
Freshwater tank empty
flowing from
Pump wired in reverse
any tap when
operated but
Pipe inlet or outlet pipe
pump runs
disconnected
Pump pipes restricted
by kinking
Blockage in pump inlet or
outlet pipe
Blocked in-line filter of
pump filter
Air leak in suction line
to pump
Pump does
Pump or tap
not run
incorrectly wired
Pump fuse blown
Battery disconnected
Pump seized or overheated
Pressure pump sensing
switch may have failed
Contacts may be faulty
Wiring connections may
be faulty
Water flows
Feed pipe to water heater
from cold tap
incorrectly connected to the
but not from
heater outlet
hot
Blockage in hot pipeline
Heater inlet or outlet pipes
kinked preventing flow
Hot tap not connected
Hot tap failed or blocked
Heater non-return valve
jammed
WAT E R FA U LT S
Remedy
Check
Check wiring, refer to pump manufacturers
instructions
Check connections
Check pipes run
Check, starting inside freshwater tank
Dismantle and clean
Check for bubbles.
Refer to pump/tap manufacturers instructions
Check wiring connection and then replace with
fuse of correct rating
Check connections
Refer to pump manufacturers servicing
instructions
Refer to pump manufacturers servicing
instructions
Check contacts in plug and socket are clean
and making contact
Check wiring connections
Refer to installation instructions
Disconnect pipes and inspect.
Check and re-route if necessary.
Check pipe and connect where required.
Disconnect and inspect.
Refer to dealer.
57

Advertisement

Table of Contents
loading