Swift Tourer Owner's Handbook Manual page 106

Owner’s service and warranty handbook
Table of Contents

Advertisement

T R UM A COMB I B OI LER
Technical data
determined in accordance with EN 624 or
Truma test
Device category
I3 B/P in accordance with EN 437
Type of gas: Liquid gas (propane / butane)
Operating pressure: 30 mbar (see type plate)
Water contents: 10 litres
Heating up time from approx. 15° C to
approx. 60° C
Boiler approx. 20 minutes (measured
according to EN 15033) Heater + boiler
approx. 80 min.
Pump pressure: max. 2.8 bar
System Pressure: max. 4.5 bar
Rated thermal output
(automatic output levels)
Gas Operation:
Combi 2 E UK: 2000 W
Combi 4 E: 2000 W / 4000 W
Electrical operation
Combi 2 E UK/ 4 E: 900 W / 1800 W
Mixed operation (gas and electrical)
Combi 2 E UK:
Combi 4 E: max. 3800 W
Gas consumption
Combi 2 E UK: 160 g/h
Combi 4 E: 160 – 320 g/h
Readiness-heat power requirement
Combi 2 E UK / 4 E :
Gas operation 5.2 g/h
104
Air delivery volume (free-blowing without
hot-air pipe)
Combi 2 E UK:
Combi 4 E: with 3 hot-air outlets max.
249 m³/h
with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Heater + Bolier
Combi 2 E UK
Combi 4 E: Short-term max. 5.6 A
(average power consumption 1.1 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Heating element FrostControl (optional):
maximum 0.4 A
Current input of 230 V
3.9 A (900 W) or 7.8 A (1800 W)
Weight (not containing water)
Heater unit - 15.1kg
Heater ubit with peripheral devices - 15.6kg