Swift Tourer Owner's Handbook Manual page 119

Owner’s service and warranty handbook
Table of Contents

Advertisement

1. Service
With this function, you can see certain
values of the boiler on the screen. The
values are updated once a second
2. Resetting the system
Using this function, the boiler can be reset
to the factory setting. After resetting, the
panel is set as follows: the boiler in Off
mode, electrical operation 1kw, LPG heating
in On mode and indoor temperature 22°C.
Other functions are disconnected.
3. OK
To leave the tool menu, press OK.
Fault messages
Gas failure
If an error occurs in the system, the display will
show the reason.
This is only displayed when the panel is on
standby.
Battery too low: If the vehicle, boat or
building has a battery voltage of less than
10.5V, the boiler stops. It is automatically reset
when the voltage reaches 11V.
Fan Failure: Faulty fan speed. In order to
reset, disconnect 12 V from the boiler and
reconnect (automatic reset after 5 minutes).
Gas failure: Gas finished. Reset by switching
off and restarting the boiler with item 1.
Overheat red fail: Overheating protection
(red cable) triggered. To reset, disconnect 12 V
from the boiler and reconnect.
Overheat blue fail: Overheating protection
(blue cable) triggered. To reset, disconnect 12
V from the boiler and reconnect.
Window open: Window open, the boiler
stops for gas. Gas operation in the boiler
starts again when the window is closed. The
electrical operation remains in function. Check
the vehicle, boat or building manual to see
whether this function is installed.
Connection failure: There is a connection
fault between boiler and panel. To reset,
disconnect 12 V from the boiler and reconnect.
Panel failure 1: Panel fault
Panel failure 2: Panel fault
+22°C
117