WAT ER FAU LTS
WATER
Fault
Water flows
from hot
tap but has
reduced flow
from cold
Reduced flow
from both hot
and cold taps
Reduced flow
from either tap
If pump motor
runs steadily
and will not
stop
58
Cause
Cold water pipe kinked
preventing flow
Blockage in cold pipe line
Cold tap not connected
Cold tap failed or blocked
Battery condition low
causing pump to
run slowly
If new taps have been fitted
they may be restricting flow
Pump needs servicing
Partially blocked pump filter
or in-line filter, if fitted
Pump outlet pipe kinked
restricting flow
Water leak
Pipe kinking restricting flow
Battery voltage may be
too low (below 10.5 volts)
Pressure Switch setting
problem
Remedy
Check and re-route if necessary
Disconnect pipes after 1st connector and
check up to tap
Refer to installation instructions
Disconnect and inspect
Check battery state of charge,
refer to electrical supply note
Disconnect and check that they have at least
1/4" (6.3mm) bore
Refer to pump servicing instructions
Dismantle and clean if necessary
Check and re-route if necessary
Check all water connections
Check and re-route if necessary
Check that there is water in the container
Adjust switch and/or re-charge battery
Check all connections in pipework.
Adjust settings.