Output Circuit - Mercury MerCruiser D2.8L D-Tronic Service Manual

Marine engines in-line diesel
Hide thumbs Also See for MerCruiser D2.8L D-Tronic:
Table of Contents

Advertisement

SERVICE MANUAL NUMBER 22

Output Circuit

1. Ensure battery is fully charged with the hydrometer test.
2. Start the engine and increase rpm to approximately 1500 rpm.
3. Check voltage reading. the voltage should be between 13.8 and 14.2 volts. If the reading
is below 13,8 volts:
4. Connect positive (+) voltmeter lead to alternator output terminal.
5. Connect negative (–) lead to a ground terminal on alternator.
6. Wiggle engine wiring harness while observing voltmeter. Meter should indicate
approximate battery voltage and should not vary. If no reading is obtained, or if reading
varies, check alternator output circuit for loose or dirty connections or damaged wiring.
90-860074--1 FEBRUARY 2002
a -
Output Wire - BLUE
b -
Excitation Wire - PURPLE
c -
Sensing Wire - RED/PURPLE
d -
Voltmeter (0-20 Volts)
e -
Ground
d
a
e
c
b
CHARGING SYSTEM
72784
Page 4B-11