SERVICE MANUAL NUMBER 22
12. Being careful not to disturb shaft alignment, remove gear. Ensure injection pump key
is properly positioned.
13. Apply Perfect Seal sealant to a new injection pump gasket.
14. Install new gasket on pump mounting studs.
15. Install pump to cylinder block.
16. Install hex nuts with flat washers and lockwashers. Temporarily only finger-tighten the
nuts.
17. Rotate pump to end of adjustment slot travel in direction shown.
Typical
90-860074--1 FEBRUARY 2002
a -
Gasket
b -
Pump Mounting Studs
b
a
a -
Hex Nuts With Flat Washers And Lockwashers (3 Total)
b -
Direction to Rotate
b
a
INJECTION PUMP
70768
70422