e. Heat sand and observe temperature on thermometer.
f.
g. Turn heat source OFF. Allow sand and components to cool.
INSTALLATION
1. Apply Perfect Seal to threads of switch / sender.
2. Counter-hold the adaptor with a separate wrench and install the switch / sender and
sealing washer.
3. Torque the switch / sender to the adapter. Maximum torque is 25 Nm (18 lb-ft). Do NOT
overtorque.
4. Connect harness wiring. Apply liquid neoprene to the terminals.
5. Refill closed cooling system.
90-860074--1 FEBRUARY 2002
71772
a -
Suitable Container
b -
Thermometer
c -
Heat Source
d -
Water Temperature Switch/Sender
e -
12 Volt Power Source and Jumper Leads
f -
Audio Warning Alarm With Jumper Lead
Replace switch / sender if it does not close (alarm ON ) within the range of
temperatures indicated in chart below.
Test Temperature
102 - 106 Degrees C (215 - 220 Degrees F.)
e
d
a
c
INSTRUMENTATION
b
Switch Condition
Closed
Page 4D-23