9-33. RPN Concealment

RPN (Residual Point Noise) on CCD is automatically
corrected (APR) during ABB (Auto Black Balance Adjust-
ment) operation. For the RPN which cannot be corrected
by APR, perform the manual RPN concealment by follow-
ing Section 9-33-1.
When there remains the RPN which cannot be concealed
even after completion of the adjustment shown in Section
9-33-1, follow the flowchart shown in Section 9-33-2.

9-33-1. Manual RPN Concealment

Use the SERVICE menu for the manual RPN concealment.
Refer to Section 4-1-2 for how to display the SERVICE
menu.
? 07
O
MANUAL RPN
OUTPUT SELECT
RPN CURSOR
TEST OUT MENU
CURSOR H POS.
CURSOR V POS.
RECORD RPN
FIELD/FRAME
Preparation
. Adjust the black balance automatically. (Refer to the
Section 4-1 in operation manual of HDW-750.)
. Complete the setting as shown below by using the setup
menu.
MENU : OPERATION
PAGE : OUTPUT SEL
ITEM : TEST OUT SELECT → HD
MENU : SERVICE
PAGE : MANUAL RPN
ITEM : FIELD/FRAME → FRAME
. When the RPN recognition is difficult since the RPN
hides behind the character on a screen or is very close to
the character :
ITEM : TEST OUT MENU → OFF
. Connect the HD color monitor to the TEST OUT
connector (on the outside panel).
HDW-750/750CE V1
:
Y
:
OFF
:
OFF
:
0
:
0
:
EXEC
: FIELD
Adjustment Procedures
n
The points adjacent to the already corrected RPN in the up,
down, right, and left directions cannot be corrected.
1. Select the channel (R, G, or B) to be corrected.
ITEM : OUTPUT SELECT → R, G, B
2. Adjust the values of H and V so that the center of the
cross cursor is aligned just over the RPN.
ITEM : RPN CURSOR → ON
ITEM : CURSOR H POS.
ITEM : CURSOR V POS.
n
One full rotation of the rotary encoder is equivalent to
the movement by one-pixel. Since the cursor occupies
the area equivalent to two pixels, the cursor moves
with two rotations of the rotary encoder.
3. Press the rotary encoder to record the RPN data
(concealed value).
ITEM: RECORD RPN → EXEC
4. "RECORD DATA OK? YES → NO" is displayed.
After confirming that the RPN is corrected, rotate the
rotary encoder until "YES" blinks.
5. Press the rotary encoder. "COMPLETE!" is displayed,
and concealment will be performed.
n
Make sure that RPN is corrected before executing the
RPN concealment.
6. If the RPN concealment is going to be executed for
another RPN, repeat steps 2 to 5.
n
When there exists an RPN that cannot be corrected
with this adjustment, follow the flowchart of the
Section 9-33-2.
Setting after Adjustment
ITEM : RPN CURSOR → OFF
ITEM : FIELD/FRAME → FIELD
9-33. RPN Concealment
9-31