11-2. Operation Procedure
11-2. Operation Procedure
11-2-1. Identifying Switches
Rotary
encoder
MENU ON/OFF switch
Use this switch to turn the VTR maintenance menu on and off. When the lid is closed, the switch is set in
the OFF position.
ON : The VTR maintenance menu is shown on the display.
OFF : The VTR maintenance menu is not shown on the display.
ESCAPE switch
Use this switch to return to the previous display.
Rotary encoder
Rotate : Rotate the rotary encoder to move the cursor in the direction of the arrow (→) to select the
desired item.
Press : Press the rotary encoder to set the selected item.
11-2-2. How to Enter VTR Maintenance Mode
1. Set the switch S1-1/AT-143 board to the ON position.
2. Set the MENU ON/OFF switch on the inside panel to the ON position to start up the maintenance
mode.
3. The TOP MENU display appears.
4. Select SERVICE and press the rotary encoder.
S <TOP MENU>
USER
USER MENU CUSTOMIZE
*
ALL
.
OPERATION
.
PAINT
.
MAINTENANCE
.
FILE
.
DIAGNOSIS
→
SERVICE
* : The above display is the TOP MENU display of the unit with serial No. 10000 series.
The ALL menu cannot be selected in the Camcorder with serial No. 70000 and No. 80000 series.
11-2
ESCAPE switch
MENU ON/OFF
switch
CANCEL/PRST
OFF
ON/SEL
ESCAPE
ON
STATUS
MENU
OFF
HDW-750/750CE V1