5-6. Operating the REFERENCE File
Saving in the Main Unit
1. Set the MENU ON/OFF switch to the ON position.
2. Create the optimum reference file data by various adjustments using the setup menu.
(For details of the respective file items of the REFERENCE file, refer to Section 4-10, "Setup Menu
List".)
3. Let the REFERENCE display of the FILE menu appear on the screen and select F.ID to set the file
ID.
O
? 05
REFERENCE
REFERENCE STORE :
REFERENCE CLEAR :
REFERENCE LOAD
REFERENCE SAVE
F.ID :
SCENE WHITE DATA:
4. Select REFERENCE STORE and execute it by pressing the rotary encoder.
5. A message appears prompting your confirmation. Select YES and press the rotary encoder.
Saving in a Memory Stick
1. Insert a Memory Stick
2. Set the MENU ON/OFF switch to the ON position.
3. Let the REFERENCE display of the FILE menu appear on the screen and select F.ID to set the file
ID.
O
? 05
REFERENCE
REFERENCE STORE :
REFERENCE CLEAR :
REFERENCE LOAD
REFERENCE SAVE
F.ID :
SCENE WHITE DATA:
4. Select REFERENCE SAVE and press the rotary encoder. The message [SAVE DATA OK?] appears.
O
? 05
REFERENCE
SAVE DATA OK?
REFERENCE STORE :
REFERENCE CLEAR :
REFERENCE LOAD
REFERENCE SAVE
F.ID :
SCENE WHITE DATA:
HDW-750/750CE V1
EXEC
EXEC
:
EXEC
:
EXEC
OFF
EXEC
EXEC
:
EXEC
:
EXEC
OFF
→
YES
NO
EXEC
EXEC
:
EXEC
:
EXEC
OFF
5-6. Operating the REFERENCE File
5-13