9-13. Flare Adjustment

9-13. Flare Adjustment
Preparation
. Lens iris → MAN
. OUTPUT/DCC switch (inside panel) → CAM/ON
. WHITE BAL switch (inside panel) → A
. Shoot a gray-scale chart to fill the entire screen of the
under-scanned picture frame and execute AWB.
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (outside panel)
Adjustment point : Open the lens iris by 1 F-stop
from the reference value
(A = 700 ± 14 mV).
Adjustment Procedure
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (outside panel)
1. Complete the setting as shown below by using the
setup menu.
MENU : PAINT
PAGE : 03*BLACK
ITEM : G FLARE → 0
9-16
2. Select a horizontal scanning line in the portion B on
the waveform monitor using the LINE SELECT
function.
3. Complete the adjustment as shown below by using the
setup menu.
MENU :
PAGE :
ITEM :
Specifications : Minimize the color difference level at
A
4. Complete the adjustment as shown below by using the
setup menu.
MENU :
PAGE :
ITEM :
Specifications : Minimize the color difference level at
5. Repeat steps 3 and 4 several times.
B
PAINT
03*BLACK
R FLARE
the portion C.
C
PAINT
03*BLACK
B FLARE
the portion C.
HDW-750/750CE V1