SECURING THE PROTECTED SITE
To read the alarm memory, refer to Chapter 5.
The "MEMORY" message will disappear only
upon re-arming the system.
C. Disarming after an alarm, with one zone still
disturbed: If the zone that alarmed in the armed
state is still disturbed, the disarming operation
will progress as shown:
PRESS
RESULTANT DISPLAY
CODE
CODE
NOT READY
NOT READY MEMORY
ARM indicator extinguishes
To read the alarm memory, refer to Chapter 5.
The "MEMORY" message will disappear only
when you rearm the system.
If you do not know how to return the disturbed
zone to normal, consult your installer.
D. Disarming with the system in a state of trouble:
If trouble is detected in the armed state, the
TROUBLE indicator on the front panel will light and
the disarming operation will progress as shown:
PRESS
RESULTANT DISPLAY
CODE
CODE
READY
READY TRBL
ARM indicator extinguishes and
sounds once per minute,
To find out what kind of trouble is being sensed, see
Chapter 5. The TRBL display will disappear, the
TROUBLE indicator will extinguish and the trouble
beeps will stop upon eliminating the cause for trouble.
E. Disarming after an alarm, with the system in a
state of trouble: The TROUBLE indicator on the
front panel will light. If the zone that alarmed while
the system was in the armed state is back to normal,
the disarming operation will progress as shown:
PRESS
RESULTANT DISPLAY
CODE
READY
CODE
READY TRBL
READY MEMORY
12
_ _ _
HH:MM
(alternating)
_ _ _
HH:MM
(alternating)
_ _ _
HH:MM
(alternating)
(alternating)
ARM indicator extinguishes and
sounds once per minute.
To find out which zone alarmed and what kind of
trouble is being sensed, see Chapter 5. The
TRBL display will disappear, the TROUBLE
indicator will extinguish and the trouble beeps will
stop upon eliminating the cause for trouble. The
MEMORY message will disappear only upon
rearming the system.
F. Disarming under Duress. If you are forcibly
compelled to disarm the system, enter the default
duress code (2580) or another code set by the
installer. Disarming will take place normally but a
silent alarm will be transmitted to the central station.

Siren Behavior

Continuously ON when initiated by a burglar zone
or a 24-hour zone, and when a user initiates a "panic
alarm".
When initiated by a fire zone (smoke is detected) ON -
ON - ON - pause - ON - ON - ON - pause - ........
and so on.
If there is nobody around to disarm the system upon
alarm and a zone remains "open", the siren will
sound for the time duration set by the installer - then
will stop. The strobe light keeps flashing until the
system is disarmed.

Display when Partitioning is enabled

In Non-Partition mode
READY
NOT READY
ARM AWAY
PLEASE EXIT NOW
AWAY
ARM HOME
AWAY HH:MM
HOME HH:MM
ARM HOME MEMORY
ARMING INSTANT
ARM HOME INSTANT
ARMING LATCHKEY
READY HH:MM
READY MEMORY
NOT READY HH:MM
NOT READY MEMORY
READY TRBL
In Partition mode (for
example partition #3)
RDY
N.RDY
P3 ARM AWAY
P3 PLS EXIT NOW
P3 AWAY
P3 ARM HOME
P3 AWAY HH:MM
P3 HOME HH:MM
P3 HOME MEM
P3 ARM INSTANT
P3 ARM HOME INST
P3 ARM LATCHKEY
P3 RDY HH:MM
P3 RDY MEM
P3 N.RDY HH:MM
P3 N.RDY MEM
P3 RDY TRBL