Start Ul/Dl; Partitioning; General Guidance - "Partitioning" Menu; Enabling / Disabling Partitions - Visonic PowerMaster-10 G2 Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10 G2:
Table of Contents

Advertisement

5.13 Start UL/DL

Note: This option is only used during the installation of panels monitored by compatible Monitoring Stations.
The "START UL/DL" menu enables the installer to initiate a call to the upload/download server. The server uploads the
PowerMaster configuration to its database and can download predefined parameters to the PowerMaster. To perform
server upload/download proceed as follows:
Step 1
Select "11:START UL/DL" menu
11:START UL/DL
 – Performing Server Upload/Download
[1]
Enter the Installer Menu and select the "11:START UL/DL" menu (see section 5.2).
[2]
After pressing the
"COMMUNICATING" - If the UL/DL server telephone number was already defined (see section 5.6.4 "Configuring
Events Reporting to Monitoring Stations"), the PowerMaster display will read "COMMUNICATING" which is
displayed during the dialing process.
"TEL# NOT DEFINED" - If the UL/DL server telephone number was not defined (see section 5.6.4 "Configuring
Events Reporting to Monitoring Stations"), the PowerMaster display will read "TEL# NOT DEFINED" which is
displayed for approx. 30 sec. and is followed by a sad (failure) tune.
"DOWNLOADING" - If communication has been established between the PowerMaster control panel and the
upload/download server, the PowerMaster display will read "DOWNLOADING" which is displayed during the
dialing process.
"DIAL ATTEMPT" - If communication has failed between the PowerMaster control panel and the
upload/download server, the PowerMaster display will read "DIALATTEMPT FAIL" which is displayed for approx.
30 sec. and is followed by a sad (failure) tune.
"DOWNLOAD OK" - After the downloaded/uploaded process has been completed successfully, the PowerMaster
display will read "DOWNLOAD OK" which is displayed for approx. 30 sec. and is followed by a happy (success)
tune.
"DOWNLOAD FAILED" - If communication has been established between the PowerMaster control panel and
the upload/download server but the downloaded/uploaded process has failed, the PowerMaster display will read
"DOWNLOAD FAILED" which is displayed for approx. 30 sec. and is followed by a sad (failure) tune.

5.14 Partitioning

5.14.1 General Guidance – "Partitioning" Menu
This menu allows you to enable/disable partitions in the system (for further details, see APPENDIX B).

5.14.2 Enabling / Disabling Partitions

To enable or disable the partition feature, proceed as follows:
Step 1
Select "12:PARTITIONING" menu
12:PARTITIONING

5.15 Operation Mode

Note: The Operation Mode feature is applicable only in specific PowerMaster variants.
5.15.1 General Guidance – "Operation Mode" Menu
This new feature allows selection of the active operation mode of the control panel in order to comply with different
standards such as EN-50131, DD243 and BS8243. Each operation mode has its own configuration, which overrides
the generic panel setup.
D-303222 PowerMaster-10/30 G2 Installer's Guide
Step 2
[1]
Press
COMMUNICATING
button, one of the following messages will appear on the control panel display:
Step 2
Select whether to "Enable" or "Disable" Partitions
Disable
5. PROGRAMMING
Step 3
[2]
to Step 1
Step 3
 to Step 1
59