APPENDIX A. Partitioning

Your system is equipped with an integrated partitioning
feature that can divide your alarm system into three distinct
areas identified as Partition 1 through 3. Partitioning can be
used in installations where shared security systems are
more practical, such as a home office or warehouse
building. When partitioned, each zone, each user code and
many of your system's features can be assigned to Partition
1 to 3.
Note: When Partition Mode is disabled, all zones, user
codes, and features of the PowerMaxExpress will operate
as in a regular unit. When partition mode is enabled, all
zones, user codes, and features of the PowerMaxExpress
are automatically assigned to Partition 1.

A1. Programming Partitions

Your system arrives with partitioning disabled.
To Enable Partitioning
A. Enter PowerMaxExpress installer Mode (see par. 4.1.5).
The PowerMaxExpress display will read "1. NEW INSTL
CODE".
B. Click the
PowerMaxExpress display will read:
1 5 . P A R T I T I O N I N G
C. Click
. The PowerMaxExpress display will
read:
D i s a b l e
D. Click the
display will read:
E n a b l e
E. Click the
display will change to:
E n a b l e
F. Click the
setting.

A2. Defining Zones

Partitioning is defined by zones that are assigned to each
partition. During programming each zone should be
assigned to one or more partitions.
To Define Zones
A. Enter PowerMaxExpress installer Mode (see par. 4.1.5).
The PowerMaxExpress display will read"1. NEW INSTL
CODE".
B. Click the
display will read:
3 D E F I N E Z O N E S
C. Click the
display will read:
Z O N E N o : - -
D. Enter
a
zone
number,
PowerMaxExpress display will read:
Z 0 5 : T Y P E - -
E. Proceed by setting the zone type, name and chime option
(see par. 4.3).
F. After setting the chime option select PARTITION. If zone
number was set to 05 the PowerMaxExpress display will
read:
36
button repeatedly until the
button. The PowerMaxExpress
button. The PowerMaxExpress
button again to confirm the new
button twice. The PowerMaxExpress
button. The PowerMaxExpress
for
example,
G. Press
corresponding partitions.
more partitions, this indicates that the zone is located
in a common area and will behave according to the
state of both partitions. (For a detailed description on
common areas, refer to the "Common Areas" section
below.)
H. Press

A3. Enrolling Keyfobs and Keypads

This section provides instructions for enrolling keyfobs and
keypads into the PowerMaxExpress system.
To Enroll a Keyfob
Keyfob transmitter enrolling involves the following steps:
A. Having entered your Installer Code successfully (see
section
(repeatedly, if necessary) until the display will read:
B. Click
C. Click the
display will read:
D. Click
E. Suppose that the Keyfob you are about to enroll is to be
designated as Keyfob No. 5. Assuming that memory
location No. 5 is free - no keyfob has yet been enrolled
to it - click the <5> key. The display will change to:
The clear space at the far right tells you that the
memory location is free.
F. Click
initiate a transmission from the chosen keyfob:
G. Initiate a transmission from the chosen keyfob by
pressing any one of its pushbuttons. In response, the
"Happy Tune" (- - - –––) will sound. When partition is
disabled, the display will read:
Proceed to step "K" below.
When partition is enabled, the display will read:
H. Click
I. Select the desired partitions that will be associated and
can be controlled by this keyfob via pushbuttons 1, 2
05.
The
and 3 on the control panel keypad.
J. Click
A dark box will appear at the far right, indicating that
the chosen Keyfob has been enrolled as Keyfob No. 5.
Z 0 5 : P 1
P 2 P 3
,
and
If a zone is assigned to two or
twice to confirm the settings.
4.1.5),
Click
the
2. ENROLLING
. The display will read:
ENROLLING TYPE
button repeatedly until the
ENROLL KEYFOB
. The display will read:
KEYFOB No:
KEYFOB No:
5
. The display will prompt you to
TRANSMIT NOW
KEYFOB No: 5
ACCESS TO PART
. The display will read
F01: P1
P2
P3
. The display will read:
KEYFOB No: 5
D-303973 PowerMaxExpress Installer's Guide
to select the desired
button
_