Table 17: Domestic Dialing Defaults Settings; Figure 37: Factory Default Display - Bosch Solution 16i Installation Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16i
Installation Manual
G E T T I N G S TA R T E D B AC K TO B A S E
The following steps are the mimimum requirements to
get the system reporting back to base. Examples assume
the panel is disarmed with no alarms and starting from
factory default settings.
1) Enter Program mode.
[1234 + MENU]
2) Set Time and Date.
[MENU 7-1-0]
3) Change Default Installer PIN.
[MENU 1-5-2]
4) Change Default Master PIN.
[MENU 1-1-1]
5) Enter Account (client) Number, Area 1.
[MENU 2-2-0]
6) Enter Base Primary Telephone Number.
[MENU 5-1-1]
7) Enter Base Secondary Telephone Number.
[MENU 5-1-2]
8) Hold Down MENU Key To Exit. S E R V I C E M O D E
Service mode when activated disables dialler reporting,
prevents all alarms and prevents all users from arming the
system.
To Turn Service Mode ON
1) Enter Program Mode.
[1234 + MENU]
2) Enter,
[MENU 7-0-8]
3) The display will show IS OFF if service mode is off or
IS ON if service mode is on.
4) Press the On or OFF key to change the service
mode state then press [OK] to exit.
SERVic
Keypads will display SErVIC on the screen when
i
service mode is active.
Note
4-4
Programming Overview
D E FAU LT I N G T H E S YS T E M
Defaulting the system will reset all programming options
back to the factory default setting. All programming
information will be erased.
To Hardware Default
1) Remove All Power To The System. AC and
Battery.
2) Press and Hold The Default Push Button
Down Then Apply Power To The System.
3) Release Button, The Panel Will Reset And
Revert To Normal Operation When Default Is
Complete.
To Software Default
1) Enter Program Mode.
[1234 +MENU]
2) Select Factory Default Option.
[MENU 7-0-4)
3) The Panel Will Reset And Revert To Normal
Operation When Defaulting Is Complete.
FDEF ?

Figure 37: Factory Default Display

You can disable factory defaulting using MENU 7-7-
i
4. If factory defaulting has been disabled you must
Note
know the installer code to perform a factory default
otherwise the system will need to be returned to your
supplier for defaulting or you can purchase a CM255
Default Unlock Key which will unlock the panel in the
field. Charges apply for defaulting if retuned to the
distributor.
D O M E S T I C T E M P L AT E D E FAU LT S
The following table list the changes that will occur when
you select domestic default.
Program Option
All Trouble Reports
All Bypass Reports
All Restore Reports
Destination 1 TX Format
Open / Close Reports
System Events Route

Table 17: Domestic Dialing Defaults Settings

Domestic Default Value
Disabled
Disabled
Disabled
Domestic Reporting
Disabled (all areas)
Log Only