5.6.2

Cable Kit

Caution – The procedure below is for the attention of qualified service engineers
only. Before touching or replacing any component inside the Sun Fire V60x and Sun
Fire V65x servers, disconnect all external cables and follow the instructions in
"Safety: Before You Remove the Cover" on page 5-2 and "Removing and Replacing
the Cover" on page 5-3. Always place the server on a grounded ESD pad and wear a
properly grounded antistatic wrist strap.
You can use the cable kit to replace one or more internal server cables. The
procedures given below assume that you are removing and replacing all of the
cables.
5.6.2.1

Sun Fire V60x Server Cable Kit Removal

Before removing the cover to work inside the system, observe the safety guidelines
previously given.
To remove cables, remove the cover and refer to Figure 5-40, Figure 5-41, and
Figure 5-42 while following these steps:
1. Remove the air baffle.
2. Remove the fan module.
3. Unscrew and remove the blue plastic flex cable retention clip from the server
board.
4. Remove all hard disk drives (including blanks) and the floppy/CD-ROM combo
drive.
5. Unplug the backplane power cable, server board auxiliary signal cable, and server
board auxiliary power cable, shown in Figure 5-40, panel 2.
6. Remove the round SCSI cable.
7. Remove the flex circuit cable (floppy/FP/IDE) that runs from the connector on the
server board to the connector on the backplane.
8. Remove the front panel cable that runs from the front panel board to the
backplane.
Chapter 5 Maintaining the Server