Power Led Does Not Light - Sun Microsystems Sun Fire V60x Manual

Table of Contents

Advertisement

To return a system with redundant processors to normal operation after an FRB2
event, follow the instructions below:
1. Reset or turn on the system.
2. Press the F2 key to select SETUP as soon as the option appears on the screen.
3. Once in the main page of the SETUP menu, use the arrow keys to select Processor
Settings then press Enter.
4. In the Processor Settings screen, select Processor Retest then select Enabled.
5. Press the F10 function key to exit the SETUP menu and save changes.
The system will then re-test both processors to make sure they are in working
condition and bring both processors back to normal operation.
Note – The 'Processor Retest' feature will return to its default 'Disabled' condition,
after this cycle is complete.
2.2.2

Power LED Does Not Light

Check the following:
Is the system operating normally? If so, the power LED is probably defective or
the cable from the front panel to the server board is loose.
Are there other problems with the system? If so, check the items listed under
"System Cooling Fans Do Not Rotate Properly" on page 2-12.
If all items are correct and problems persist, contact your service representative or
authorized dealer for help.
Chapter 2 Troubleshooting Specific Problems
2-9